Passenger Information System
Passenger Information System
e-INFO is a real time interface software between passenger information displays and signalling interlocking systems at metros, tram lines, commuter lines and mainline railway applications.
e-INFO is a real time interface software between passenger information displays and signalling interlocking systems at metros, tram lines, commuter lines and mainline railway applications.
Technical Specification

e-Info Server
The system is designed to include 2 modules, e-INFO Server and e-INFO Client Control Application.
In addition to real time location/arrival time information of the trains, the system is capable to provide other immediate data such as dynamic messages, emergency notifications, etc.
e-INFO has a user friendly and flexible operator interface.
It is designed as multiple servers working with redundancy and to perform real-time replication.
The communication with both active and passive servers is constantly checked, and when the active server stops communicating, it continues to communicate with the standby server.
Multi-platform support with flexible structure.

Technical Specifications
e-Info Server
The system is designed to include 2 modules, e-INFO Server and e-INFO Client Control Application.
In addition to real time location/arrival time information of the trains, the system is capable to provide other immediate data such as dynamic messages, emergency notifications, etc.
e-INFO has a user friendly and flexible operator interface.
It is designed as multiple servers working with redundancy and to perform real-time replication.
The communication with both active and passive servers is constantly checked, and when the active server stops communicating, it continues to communicate with the standby server.
Multi-platform support with flexible structure.
e-Info Control Application
User friendly and powerful interface.
- 3 different levels of user authorization.
Administrator Mode
Operator Mode
Maintenance Mode
According to their authorization levels, users can;
Send an emergency message to all system, to a group of displays or any one of the panels.
It can send messages to the desired LED panels from ready-made lists.
Add new messages easily into the message list in the Administrator User.
Blank out any of the information displays within the system.
Monitor the situation of any of system displays instantly.
Real-time monitoring of train locations.
Add new users based on predefined user groups through the Administrator User.
Track and monitor real-time and historical system statuses in the Event Center.
Generating a detailed daily plan based on the service timetables.


e-Info Control Application
User friendly and powerful interface.
- 3 different levels of user authorization.
Administrator Mode
Operator Mode
Maintenance Mode
According to their authorization levels, users can;
Send an emergency message to all system, to a group of displays or any one of the panels.
It can send messages to the desired LED panels from ready-made lists.
Add new messages easily into the message list in the Administrator User.
Blank out any of the information displays within the system.
Monitor the situation of any of system displays instantly.
Real-time monitoring of train locations.
Add new users based on predefined user groups through the Administrator User.
Track and monitor real-time and historical system statuses in the Event Center.
Generating a detailed daily plan based on the service timetables.

e-INFO Led Displays
Technical Specification
High brightness led displays provide long distance clear visibility in outdoor conditions.
Supports Telnet, SNMP, UDP, Modbus TCP, Modbus RTU and SSH etc. communication protocols via Ethernet or RS485 connection.
It has an aluminum housing with IP65 protection against water and dust.
It is as lightweight and ergonomically designed as possible for easy installation and maintenance.
Ambient Air Temperature for Operation : -20 to +70˚C
Rated Supply Voltage for Operation : 90 – 270 V AC
Designed According to European Standard
Complies with EN 62368-1 safety standard for audio, video, and IT equipment.
EMC compliance according to EN-55032 / 55035 standards
Compliance with environmental requirements according to EN-60529-2-11/27/30/64

e-INFO Led Displays
Technical Specification
High brightness led displays provide long distance clear visibility in outdoor conditions.
Supports Telnet, SNMP, UDP, Modbus TCP, Modbus RTU and SSH etc. communication protocols via Ethernet or RS485 connection.
It has an aluminum housing with IP65 protection against water and dust.
It is as lightweight and ergonomically designed as possible for easy installation and maintenance.
Ambient Air Temperature for Operation : -20 to +70˚C
Rated Supply Voltage for Operation : 90 – 270 V AC
Designed According to European Standard
Complies with EN 62368-1 safety standard for audio, video, and IT equipment.
EMC compliance according to EN-55032 / 55035 standards
Compliance with environmental requirements according to EN-60529-2-11/27/30/64